... with own bearings |
OG 6 |
Square-wave cycles per turn: |
100 - 512 |
|
Servo flange |
Max. output frequency: |
120 kHz |
Solid shaft d= 6 mm |
Logic level: |
HTL (C), TTL, TTL (R) |
|
Permissible encoder temperature: |
-20 °C to +70 °C |
|
Connection: |
Internal connection terminals |
|
Weight: |
approx. 200 g |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 54 |
Ex II 3G 3D |
|
OG 60 • HOG 60 |
Square-wave cycles per turn: |
max. 10,000 |
|
Servo flange (OG 60) |
Max. output frequency: |
250 kHz |
Solid shaft d= 6 mm (OG 60) |
Logic level: |
HTL (C), TTL, TTL (R) |
Hollow shaft with clamping ring up to d= 12 mm (HOG 60) |
Permissible encoder temperature: |
-30 °C to +85 °C |
Connection: |
Plug connection |
High resolution |
Weight: |
approx. 260 g (OG 60) approx. 250 g (HOG 60) |
|
Shock resistance (6 ms): |
3,000 m/s² |
|
Protection class: |
IP 65 |
Ex II 3G 3D |
|
OG 70 • HOG 70 |
Square-wave cycles per turn: |
50 - 10,000 |
|
Servo flange (OG 70) |
Max. output frequency: |
250 kHz |
Solid shaft d= 6 mm (OG 70) |
Logic level: |
HTL (C), TTL, TTL (R) |
Hollow shaft up to d= 14 mm (HOG 70) |
Permissible encoder temperature: |
-20 °C to +85 °C |
Connection: |
Internal connection terminals |
|
Weight: |
approx. 360 g (OG 70) approx. 240 g (HOG 70) |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
OG 71 • HOG 71 |
Square-wave cycles per turn: |
OG 71: 100 up to 1,024 HOG 71: 64 up to 2,048 |
|
Servo flange (OG 71) |
Max. output frequency: |
120 kHz |
Solid shaft d= 6 mm (OG 71) |
Logic level: |
HTL (C), TTL, TTL (R) |
Hollow shaft up to d= 14 mm (HOG 71) |
Permissible encoder temperature: |
-20 °C to +85 °C |
Connection: |
Internal terminal strip |
|
Weight: |
approx. 360 g (OG 71) approx. 240 g (HOG 71) |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
AHE 7 • AFE 7 |
Square-wave cycles per turn: |
60 - 5,000 |
|
Version US of OG 71/•HOG 71 |
Max. output frequency: |
120 kHz |
1/2" hollow shaft (AHE 7) |
Logic level: |
HTL (C), TTL, TTL (R) |
3/8" servo flange (AFE 7) |
Permissible encoder temperature: |
-30 °C to +70 °C |
NPT 1/2" fitting |
Connection: |
Internal connection terminals |
|
Weight: |
approx. 240 g (AHE 7) approx. 380 g (AFE 7) |
|
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 |
|
|
HOG 75 • HOG 75 K |
Square-wave cycles per turn: |
250 - 2,500 |
|
Through-hole hollow shaft with clamping ring up to d= 26 mm (HOG 75) |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL |
Cone shaft 1:10 (HOG 75 K) |
Permissible encoder temperature: |
-30 °C to +85 °C |
|
Connection: |
Internal connection terminals |
|
Weight: |
approx. 320 g |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
OG 8 • HOG 8 |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11mm (OG 8) |
Max. output frequency: |
120 kHz |
Through-hole hollow shaft with clamping ring up to d= 16 mm (HOG 8) |
Logic level: |
HTL (C), TTL, TTL (R) |
Permissible encoder temperature: |
-30 °C to +85 °C |
|
Connection: |
Internal connection terminals |
|
Weight: |
approx. 700 g (OG 8) approx. 550 g (HOG 8) |
|
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 54 |
|
|
OG 9 |
Square-wave cycles per turn: |
1 - 1,250 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-30 °C to +100 °C |
|
Connection: |
Terminal box |
|
Weight: |
approx. 900 g |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 55 |
Ex II 3G 3D |
|
OG 90 |
Square-wave cycles per turn: |
1,000 - 10,000 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
250 kHz |
High HTL output current |
Logic level: |
HTL (C), TTL, TTL (R) |
High resolution |
Permissible encoder temperature: |
-30 °C to +85 °C |
|
Connection: |
Terminal box |
|
Weight: |
approx. 1.5 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 55 |
|
|
HOG 9 • HOG 9 G |
Square-wave cycles per turn: |
1 - 2,500 |
|
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Option: Cone shaft 1:10 |
Permissible encoder temperature: |
-30 °C to +100 °C |
High HTL output current |
Connection: |
Plug connection |
Bearing at each end |
Weight: |
approx. 700 g (HOG 9) |
Protection against shaft currents |
|
approx. 1,100g (HOG 9G) |
Twin encoder HOG 9 G |
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
FOG 9 |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-30 °C to +100 °C |
|
Connection: |
Plug connection |
|
Weight: |
approx. 860 g |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
POG 9 |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-30 °C to +100 °C |
Twin encoder POG 9 G |
Connection: |
Terminal box |
|
Weight: |
approx. 1.3 kg |
|
Shock resistance (1 ms): |
3,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
POG 9 G |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-30 °C to +100 °C |
|
Connection: |
Terminal box |
|
Weight: |
approx. 1.7 kg |
|
Shock resistance (1 ms): |
3,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
POG 90 |
Square-wave cycles per turn: |
1,024 - 10,000 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
250 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-20 °C to +85 °C |
High resolution |
Connection: |
large terminal box |
|
Weight: |
approx. 1.5 kg |
|
Shock resistance (11 ms): |
1,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
HOG 10 |
Square-wave cycles per turn: |
1 - 2,500 |
|
Hollow shaft with clamping element up to d= 20 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Option: Cone shaft 1:10 |
Permissible encoder temperature: |
-40 °C to +100 °C -50 °C to +100 °C (optional) |
High HTL output current |
Connection: |
Internal connection terminals or large terminal box |
Protection against shaft currents |
Weight: |
approx. 1.6 kg |
Twin encoder HOG 10 G |
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
HOG 10 G |
Square-wave cycles per turn: |
1 - 2,500 |
|
Hollow shaft with clamping element up to d= 20 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Option: Cone shaft 1:10 |
Permissible encoder temperature: |
-40 °C to +100 °C -50 °C to +100 °C (optional) |
High HTL output current |
Connection: |
Large terminal box |
Protection against shaft currents |
Weight: |
approx. 2.2 kg |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
HOG 100 |
Square-wave cycles per turn: |
1,024 - 10,000 |
|
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: |
250 kHz |
Logic level: |
HTL, TTL |
Option: Cone shaft 1:10 |
Permissible encoder temperature: |
-30 °C to +85 °C |
High HTL output current |
Connection: |
Internal connection terminals or large terminal box |
High resolution |
Weight: |
approx. 1.5 kg |
Protection against shaft currents |
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
POG 10 |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-40 °C to +100 °C -50 °C to +100 °C (optional) |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
Connection: |
Large terminal box |
Weight: |
approx. 1.6 kg |
Twin encoder POG 10 G |
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 66 |
|
Ex II 3G 3D |
|
POG 10 G |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
High HTL output current |
Logic level: |
HTL, TTL, TTL (R) |
Bearing at each end |
Permissible encoder temperature: |
-40 °C to +100 °C -50 °C to +100 °C (optional) |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
Connection: |
Large terminal box |
Weight: |
approx. 2.4 kg |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 66 |
|
Ex II 3G 3D |
|
HOG 11 (Offshore) |
Square-wave cycles per turn: |
1 - 2,500 |
|
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: |
120 kHz |
Option: Cone shaft 1:10 |
Logic level: |
HTL, TTL, TTL (R) |
Protection against inductive shaft currents |
Permissible encoder temperature: |
-30 °C to +100 °C |
Special corrosion protection e.g. for offshore |
Connection: |
Large terminal box |
Option: Hybrid bearing |
Weight: |
approx. 1.6 kg |
Option: Earthing brush for capacitive shaft currents |
Shock resistance (6 ms): |
2,500 m/s² |
Option: Heating for use down to -55°C |
Twin encoder HOG 11 G |
Protection class: |
IP 67 |
Ex II 3G 3D |
|
HOG 11 G (Offshore) |
Square-wave cycles per turn: |
1 - 2,500 |
|
Hollow shaft with clamping element up to d= 16 mm |
Max. output frequency: |
120 kHz |
Option: Cone shaft 1:10 |
Logic level: |
HTL, TTL, TTL (R) |
Protection against inductive shaft currents |
Permissible encoder temperature: |
-30 °C to +100 °C |
Special corrosion protection e.g. for offshore |
Connection: |
Large terminal box |
Option: Hybrid bearing |
Weight: |
approx. 2.2 kg |
Option: Earthing brush for capacitive shaft currents |
Option: Heating for use down to -55°C |
Shock resistance (6 ms): |
2,500 m/s² |
|
Protection class: |
IP 67 |
Ex II 3G 3D |
|
POG 11 (Offshore) |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
Logic level: |
HTL, TTL, TTL (R) |
Permissible encoder temperature: |
-30 °C to +100 °C |
Special corrosion protection e.g. for offshore |
Connection: |
Large terminal box |
Option: Hybrid bearing |
Weight: |
approx. 1.8 kg |
Option: Heating for use down to -55°C |
Shock resistance (6 ms): |
3,000 m/s² |
Twin encoder POG 11 G |
Protection class: |
IP 67 |
Ex II 3G 3D |
|
POG 11 G (Offshore) |
Square-wave cycles per turn: |
1 - 2,500 |
|
EURO flange B10, solid shaft d= 11 mm |
Max. output frequency: |
120 kHz |
Protection against inductive shaft currents with isolated coupling (e. g. K 35) |
Logic level: |
HTL, TTL, TTL (R) |
Permissible encoder temperature: |
-30 °C to +100 °C |
Special corrosion protection e.g. for offshore |
Connection: |
Large terminal box |
Option: Hybrid bearing |
Weight: |
approx. 2.4 kg |
Option: Heating for use down to -55°C |
Shock resistance (6 ms): |
3,000 m/s² |
|
Protection class: |
IP 67 |
Ex II 3G 3D |
|
HOG 12 |
Square-wave cycles per turn: |
600, 1,024 |
|
Through-hole hollow shaft with clamping ring up to d= 45 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL (C), TTL, TTL (R) |
Permissible encoder temperature: |
-30 °C to +85 °C |
|
Connection: |
Cable connection |
|
Weight: |
approx. 1 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 54 |
|
|
HOG 131 (Offshore) |
Square-wave cycles per turn: |
1,024 - 3,072 |
|
Through-hole hollow shaft with clamping ring up to d= 36 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Permissible encoder temperature: |
-40 °C to +100 °C |
|
Connection: |
Large terminal box |
|
Weight: |
approx. 4 kg |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
EGZ 14 • AG 14 |
Square-wave cycles per turn: |
250 - 2,500 |
|
Through-hole hollow shaft up to d= 70 mm |
Max. output frequency: |
120 kHz |
Especially for lift drives |
Logic level: |
HTL (C), TTL, TTL (R) |
|
Permissible encoder temperature: |
-30 °C to +70 °C |
|
Connection: |
Plug connection (EGZ 14) Terminal box or plug connection (AG 14) |
|
Weight: |
approx. 1.2 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 20, IP 54 |
|
|
HOG 16 |
Square-wave cycles per turn: |
250 - 2,500 |
|
Through-hole hollow shaft with clamping element up to d= 38 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
High HTL output current |
Permissible encoder temperature: |
-20 °C to +100 °C |
Slip-ring earthing contact |
Connection: |
Terminal box |
Option: Redundant scanning |
Weight: |
approx. 4 kg |
|
Shock resistance (6 ms): |
3,000 m/s² |
|
Protection class: |
IP 66 |
Ex II 3G 3D |
|
HOG 161 |
Square-wave cycles per turn: |
250 - 2,048 |
|
Through-hole hollow shaft with clamping ring up to d= 75 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Option: Redundant scanning |
Permissible encoder temperature: |
-20 °C to +85 °C |
|
Connection: |
Terminal box |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 54 |
|
|
|
Ex II 3G 3D |
|
HOG 163 (Offshore) |
Square-wave cycles per turn: |
250 - 5,000 |
|
Through-hole hollow shaft with clamping ring up to d= 75 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Insulated bearings |
Permissible encoder temperature: |
-30 °C to +85 °C |
Special corrosion protection |
Connection: |
Large terminal box |
Option: Redundant scanning |
Weight: |
approx. 3.5 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 |
Ex II 3G 3D |
|
HOG 165 (Offshore) |
Square-wave cycles per turn: |
250 - 5,000 |
|
Hollow shaft with clamping element up to d= 38 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Special corrosion protection |
Permissible encoder temperature: |
-30 °C to +100 °C |
Option: Protection against shaft currents |
Connection: |
Large terminal box |
Option: Slip-ring earthing contact |
Weight: |
approx. 4 kg |
Option: Redundant scanning |
Shock resistance (6 ms): |
3,000 m/s² |
|
Protection class: |
IP 67 |
Ex II 3G 3D |
|
HOG 22 • HOG 220 |
Square-wave cycles per turn: |
HOG 22: (720 - 4,000) HOG 220: (1,024) |
|
Through-hole hollow shaft with clamping ring up to d= 115 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HOG 22: HTL (C), TTL, TTL (R) HOG 220: HTL, TTL, TTL (R) |
|
Permiss, ible encoder temperatur, e, : |
-30 °C to +85 °C |
|
Connection: |
Terminal box or plug connection |
|
Weight: |
approx. 8.8 kg |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
HOG 22: IP 54 HOG 220: IP 56 |
Ex II 3G 3D |
|
HOG 28 |
Square-wave cycles per turn: |
1,024 - 2,048 |
|
Through-hole hollow shaft up to d= 150 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL (C), TTL, TTL (R) |
|
Permissible encoder temperature: |
-30 °C to +85 °C |
|
Connection: |
Plug connection |
|
Weight: |
approx. 20 kg |
|
Shock resistance (6 ms): |
2,000 m/s² |
|
Protection class: |
IP 54 |
Ex II 3G 3D |
|
HML 131 M |
Square-wave cycles per turn: |
128 - 2,048 |
|
Hollow shaft up to d= 36 mm |
Max. output frequency: |
200 kHz |
Operable under oil |
Logic level: |
HTL (C), TTL, TTL (R) |
Permissible encoder temperature: |
-20 °C to +90 °C |
Magnetic sensing |
Connection: |
Special connector |
Redundant sensing |
Weight: |
approx. 2.2 kg |
|
Shock resistance (12 ms): |
2,000 m/s² |
|
Protection class: |
IP 68 |
|
|
... without own bearings |
|
HG 6 |
Square-wave cycles per turn: |
100 - 512 |
|
Servo flange |
Max. output frequency: |
120 kHz |
Hollow shaft up to d= 16 mm |
Logic level: |
HTL (C), TTL, TTL (R) |
Rugged construction without own bearings for very high speeds |
Permissible encoder temperature: |
-20 °C to +85°C |
Connection: |
Internal connection terminals |
Incremental disk protected in axial and radial direction |
Weight: |
approx. 180 g |
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 / IP 23 |
Without own bearings |
|
HG 16 |
Square-wave cycles per turn: |
250 - 2,500 |
|
Through-hole hollow shaft with clamping ring up to d= 45 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL, TTL, TTL (R) |
Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
Permissible encoder temperature: |
-30 °C to +100°C |
Connection: |
Terminal box, Option: Plug connection |
Option: Redundant scanning |
Weight: |
approx. 2.4 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 56 |
Without own bearings |
|
HG 18 • HG 22 |
Square-wave cycles per turn: |
HG 18: 250 - 2,500 HG 22: 720 - 4,000 |
|
Through-hole hollow shaft with clamping ring up to d= 110 mm |
Max. output frequency: |
120 kHz |
Logic level: |
HTL (C), TTL, TTL (R) |
Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
Permissible encoder temperature: |
-30 °C to +70°C |
Connection: |
Terminal box, Option: Plug connection |
Option: Redundant scanning |
Weight: |
HG 18: approx. 4.2 kg HG 22: approx. 5.8 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
HG 18: IP 54, HG 22: IP 44 |
Without own bearings |
|
HG 21 • HG 211 |
Square-wave cycles per turn: |
2,500 |
|
Through-hole hollow shaft up to d= 95 mm |
Max. output frequency: |
120 kHz Option: 160 kHz |
Logic level: |
HTL (C), TTL, TTL (R) |
Axial displacement max. - 0.5 mm, +1.5 mm Option: up to +2.5 mm |
Permissible encoder temperature: |
-30 °C to +70 °C |
Connection: |
Connector |
Option: redundant scanning |
Weight: |
approx. 5.8 kg |
|
Shock resistance (6 ms): |
1,000 m/s² |
|
Protection class: |
IP 44 |
Without own bearings |
|
HMC 16 (M) + HEAG 158 V (M) |
Square-wave cycles per turn: |
128 - 8,192 |
|
Hollow shaft up to d= 55 mm |
Max. output frequency: |
2,000 kHz |
Magnetic sensing |
Logic level: |
HTL, TTL |
Permissible encoder temperature: |
-30 °C / 0 °C to +70 °C / 105 °C |
Redundant sensing (optional) |
Connection: |
12 pin mating connector (male contacts) |
|
Weight: |
approx. 2.4 kg |
|
Shock resistance (12 ms): |
3,000 m/s² |
|
Protection class: |
HMC 16 (M) - IP 68 HEAG 158 V (M) - IP 65 |
|
|
MHGE 100 B5 |
Square-wave cycles per turn: |
64 ... 4096 |
|
Through-hole hollow shaft with d= 20 ... 80 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-40 °C up to +100 °C |
Option: additional incremental signals |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGE 200 B5 |
Square-wave cycles per turn: |
128 ... 8192 |
|
Through-hole hollow shaft with d= 50 ... 180 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-40 °C up to +100 °C |
Option: additional incremental signals |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGE 400 B5 |
Square-wave cycles per turn: |
256 ... 16384 |
|
Through-hole hollow shaft with d= 100 ... 380 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-40 °C up to +100 °C |
Option: additional incremental signals |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGE 800 B5 |
Square-wave cycles per turn: |
512 ... 32768 |
|
Through-hole hollow shaft with d= 380 ... 740 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-40 °C up to +100 °C |
Option: additional incremental signals |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGP 100 B5 |
Square-wave cycles per turn: |
64, 128, ... 1024, ... 131072 |
|
Through-hole hollow shaft with d= 20 ... 80 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-20 °C up to +85 °C |
Option: Error output |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGP 200 B5 |
Square-wave cycles per turn: |
128, 256, ... 1024, ... 262144 |
|
Through-hole hollow shaft with d= 50 ... 180 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-20 °C up to +85 °C |
Option: Error output |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
MHGP 400 B5 |
Square-wave cycles per turn: |
256, 512, 1024, ... 524288 |
|
Through-hole hollow shaft with d= 100 ... 380 mm |
Logic level: |
HTL, TTL |
Large permissible axial displacement |
Max. output frequency: |
300 kHz |
Large permissible air gap tolerance |
Permissible encoder temperature: |
-20 °C up to +85 °C |
Option: Error output |
Connection: |
12 pole flange socket (ccw, pins) |
|
Vibration resistance (55 Hz ... 2000 Hz): |
300 m/s² |
|
Shock resistance (2 ms): |
3.000 m/s² |
|
Protection class: |
wheel IP 68 / head IP 67 |
|
|
Technical modifications reserved. |